Mechanical TestingExperimental assessment of the load-bearing capacity of specimens incorporating Pin-type Pile Joint.
Conclusion: Based on the overall test results, the pin-type joint can be considered to have strength equivalent to that of the reinforced concrete pile body under compressive, shear, bending and tensile loads.
Title page and introductory section of the scientific and technical report on mechanical testing.
Corrosion TestingTest specimens consisting of concrete piles with PPJ were exposed to an environment corresponding to a highly aggressive environment as defined in Table X5 of Russian Code SP 28.13330.2017.
Conclusion: Based on the overall results of tests lasting 6,480 hours (270 days), the PPJ can be considered suitable for connecting precast reinforced concrete piles exposed to highly aggressive soil and groundwater environments, assuming a design service life of 50 years for the structure being built.
Title page and introductory section of the scientific and technical report on corrosion testing.